DC Power Supply Cabinet DC Panel

DC power supply cabinet (microcomputer control) is used in large, medium and small power plants and substations, as the normal operation and accident state of high voltage switch, relay protection, automatic control, accident lighting, lighting and sound signals required DC power supply; It can also be used in metallurgy, railway, mining, petrochemical, post and telecommunications, communications, medical and health care, banking, hotels, high-rise buildings and computer networks and other industries required DC power supply; Microcomputer controlled DC power supply cabinet can be used for unattended, remote centralized monitoring of power plants, substations and other industries DC power supply.

EMAIL

General:

The product can also be used in metallurgy, railway, mining, petrochemical, post and telecommunications, communications, medical and health care, banking, hotels, high-rise buildings and computer networks and other industries required DC power supply; Microcomputer controlled DC power supply cabinet can be used for unattended, remote centralized monitoring of power plants, substations and other industries DC power supply.

Service Environment

  • Altitude :2000m and below (if more than 2000m, can be negotiated with the company);

  • Ambient temperature :-5℃~+40℃;

  • Relative humidity: the daily average is not more than 85%, (+25℃);

  • Note: Special conditions can be negotiated with the company.

Key Feature

  • The product has good anti-interference performance

  • The insulation detection device monitors the insulation condition of the bus at any time

  • The microcomputer controlled DC power supply cabinet can communicate with the upper microcomputer

  • The product is equipped with two charging float charging devices for mutual backup

Technical Data


Serial number

Rated battery capacity Ah

Battery output voltageV

Rated current of controllerA

Joint impulse currentA

Counter quantity

GZDW-20/220

20

220

5

60

1

GZDW-38/220

38

220

5

100

2

GZDW-50/220

50

220

8

120

2

GZDW-65/220

65

220

10

120

2

GZDW-100/220

100

220

10

240

2~3

GZDW-150/220

150

220

15

480

3~4

GZDW-200/220

200

220

20

480

3~4

GZDW-300/220

300

220

30

600

4~5

GZDW-20/110

20

220

5

60

1

GZDW-38/110

38

220

5

100

1

GZDW-50/110

50

220

8

120

2

GZDW-65/110

65

220

10

120

2

GZDW-100/110

100

220

10

240

2

GZDW-150/110

150

220

15

480

3~4

GZDW-200/110

200

220

20

480

3~4

GZDW-300/110

300

220

30

600

3~4

Drawing


GDZW.png


INQUIRY